Skip to content
Manufacturing wires & cables in Jaipur since 2010 Made in Jaipur since 2010
Monday to Saturday, 9:00 am – 6:00 pm +91 63753 71516
Tested on every run — not sampled at the end — POLY VSP Wires & Cables
Quality

Tested on every run — not sampled at the end

Insulation resistance, dielectric strength and dimensions are checked as part of production, so a batch cannot reach packing having skipped a gate.

Process

The four gates every batch passes

Each gate has a defined check and a record. If a check fails, the batch is corrected before the next stage — not sorted afterwards.

01

Copper in

Purity and continuity of the copper supply are verified before drawing. Conductivity starts with the metal, not the machine.

02

Drawing & annealing

Diameter and anneal are held to the construction sheet. Even annealing is what gives a winding wire its flex life inside a motor.

03

Insulation & bonding

Layer thickness, gel bonding, tape overlap and concentricity are checked on the line for each construction — PVC, TPR, gel bonded or taped.

04

Electrical & dimensional test

Insulation resistance (20 GΩ on the gel bonded range), dielectric behaviour and finished dimensions, then packing with a dispatch record.

What we test, and why it matters to you

Specifications
Insulation resistanceMeasured on the wound wire and on finished cable. Low IR is the first sign of moisture ingress — the failure that kills submersible motors.
Dielectric strengthConfirms the insulation survives the voltage stress of the application, with margin.
Conductor dimensionsDiameter and strand count, so resistance per metre matches the quoted size.
Insulation thicknessLayer thickness and concentricity, so the cable fits the slot or gland it was specified for.
Mechanical behaviourFlex and abrasion behaviour in handling and installation — checked on constructions where it decides service life.
Packing & recordsLength, labelling and dispatch records, so a query can be traced back to the batch.
Multi-core cable cross section — POLY VSP Wires & Cables

Documentation

Test certificates, material details and specification sheets are issued with supply where the order requires them. Ask for the documentation you need at enquiry stage and it is quoted along with the material.

Ask for test documentation

Materials

The three decisions that set wire quality

Copper

Oxygen-free, annealed bare copper. No mixed scrap, no substitution that shows up as heat in service.

Insulation & gel

Bonded polyester gel, BOPP / Mylar tape, PVC, TPR, modified PA, silicon and thermoset polymers — specified per product, tested per batch.

Construction

Single, double and triple sheathed builds, safety walls and water-treeing resistant designs for wet, buried and overhead service.

Want our test parameters before you order?

Tell us the application and the standard you work to. We will send the construction sheet and the tests we run against it.

Call now WhatsApp Get a quote